espanol-chica
ingles-chica

HOSPITAL LINE

We are manufacturers and suppliers for the medical industry in more than 15 countries.
We specialize in isolated IT Networks for hospital facilities.

Need advice?

ISOLATION TRANSFORMER

Isolation transformer for IT Networks for hospital group rooms
2a and 2b according to standards IEC 61558-2-15 y AEA 90364
section 7-710.

MAIN TECHNICAL CHARACTERISTICS:

  • Type: single phase dry isolation.
  • Power Range: from 3,15 kVA to 8 kVA.
  • Relation: 1:1 with a maximum nominal voltage 0f 230 Vac.
  • Vacuum current: less than 3% of nominal current (lnom).
  • Connection current: less than 12 times nominal current.
  • Short circuit voltage: less than 3% of the nominal voltage.
  • Thermal class: H class isolation
  • Isolation level: 3 kV
  • Dielectric strength: more than 500 Mohms.
  • Earth leakage current: less than 0.1 mA
  • Noise level: less than 40 dB at 30 cm distance and at nominal power.
  • Electrostatic screen between primary and secondary.
  • Leakage monitoring connection, in the middle of secondary winding to isolated terminal.
  • Temperature sensor: PTC or Pt 100 type.
  • High overload capacity.

ISOLATED LINE MONITOR

General characteristics:

  • Easy programming
  • Graphic, Luminous and Audible Information.
  • Connection to Remote Repeaters
  • No interference with other equipment.
  • Wide Range in Voltages and Frequencies

Warnings and alarms

  • Total Probable Hazard Current, THC.
  • Isolation Transformer Overload.
  • Isolation Transformer Over temperature.
  • Isolated line high voltage
  • Isolated line low voltage
  • Isolated line resistance
  • Isolated line impedance
  • ground connection continuity

VITA INSULATION BOARD

Vita insulation board for hospital facilities with network switch,
It is designed according to regulations AEA section 7-710 and to
the applicable IEC standards.

  • Automatic switch between main and alternative network.
  • UPS rodeo key.
  • Isolation transformer for hospital use.
  • Earth leakage impedance monitor (THC).
  • Control and protection elements.
  • Alarms:
    • Earth leakage current, THC
    • Transformer overload
    • Over transformer temperature
    • High and low isolated net voltage

Leave your query

    Or send us email at info@vitaguard.com.ar

    OUR COMPANY

    We are a company dedicated to manufacture Dry Isolation Electric Transformers for Networks, IT, Isolation Monitors for Hospital Facilities and Insulation Boards, Isolation Switching and Monitoring for IT Isolated Networks in hospital environments.

    We comply with International Standards such as IEC-DNI / VDE so we are qualified to supply markets around the world.